Host HA is a set of L2 and L3 features supporting high availability for hosts, including multi-Chassis Link Aggregation (MLAG) for L2 and redistribute neighbor (an experimental L3 feature).

Multi-Chassis Link Aggregation, or MLAG, enables a server or switch with a two-port bond (such as a link aggregation group/LAG, EtherChannel, port group, or trunk) to connect those ports to different switches and operate as if they are connected to a single, logical switch. This provides greater redundancy and greater system throughput.

Dual-connected devices can create LACP bonds that contain links to each physical switch. Thus, active-active links from the dual-connected devices are supported even though they are connected to two different physical switches.

A basic setup looks like this:

The two switches, S1 and S2, known as peer switches, cooperate so that they appear as a single device to host H1's bond. H1 distributes traffic between the two links to S1 and S2 in any manner that you configure on the host. Similarly, traffic inbound to H1 can traverse S1 or S2 and arrive at H1. 

Contents

 (Click to expand)

MLAG Requirements

MLAG has these requirements:

  • There must be a direct connection between the two peer switches implementing MLAG (S1 and S2). This is typically a bond for increased reliability and bandwidth.
  • There must be only two peer switches in one MLAG configuration, but you can have multiple configurations in a network for switch-to-switch MLAG (see below).
  • The peer switches implementing MLAG must be running Cumulus Linux version 2.5 or later.
  • You must specify a unique clag-id for every dual-connected bond on each peer switch; the value must be between 1 and 65535 and must be the same on both peer switches in order for the bond to be considered dual-connected.
  • The dual-connected devices (hosts or switches) must use LACP (IEEE 802.3ad/802.1ax) to form the bond. The peer switches must also use LACP.

More elaborate configurations are also possible. The number of links between the host and the switches can be greater than two, and does not have to be symmetrical:

Additionally, since S1 and S2 appear as a single switch to other bonding devices, pairs of MLAG switches can also be connected to each other in a switch-to-switch MLAG setup:

In this case, L1 and L2 are also MLAG peer switches, and thus present a two-port bond from a single logical system to S1 and S2. S1 and S2 do the same as far as L1 and L2 are concerned. For a switch-to-switch MLAG configuration, each switch pair must have a unique system MAC address. In the above example, switches L1 and L2 each have the same system MAC address configured. Switch pair S1 and S2 each have the same system MAC address configured; however, it is a different system MAC address than the one used by the switch pair L1 and L2.

LACP and Dual-Connectedness

In order for MLAG to operate correctly, the peer switches must know which links are dual-connected, or are connected to the same host or switch. To do this, specify a clag-id for every dual-connected bond on each peer switch; the clag-id must be the same for the corresponding bonds on both peer switches. Link Aggregation Control Protocol (LACP), the IEEE standard protocol for managing bonds, is used for verifying dual-connectedness. LACP runs on the dual-connected device and on each of the peer switches. On the dual-connected device, the only configuration requirement is to create a bond that will be managed by LACP. 

On each of the peer switches the links connected to the dual-connected host or switch must be placed in the bond. This is true even if the links are a single port on each peer switch, where each port is placed into a bond, as shown below:

All of the dual-connected bonds on the peer switches have their system ID set to the MLAG system ID. Therefore, from the point of view of the hosts, each of the links in its bond is connected to the same system, and so the host will use both links.

Each peer switch periodically makes a list of the LACP partner MAC addresses of all of their bonds and sends that list to its peer (using the clagd service; see below). The LACP partner MAC address is the MAC address of the system at the other end of a bond, which in the figure above would be hosts H1, H2 and H3. When a switch receives this list from its peer, it compares the list to the LACP partner MAC addresses on its switch. If any matches are found and the clag-id for those bonds match, then that bond is a dual-connected bond. You can also find the LACP partner MAC address in the /sys/class/net/<bondname>/bonding/ad_partner_mac sysfs file for each bond.

Understanding Switch Roles

Each MLAG-enabled switch in the pair has a role. When the peering relationship is established between the two switches, one switch will be in primary role, and the other one will be in secondary role. When an MLAG-enabled switch is in the secondary role, it does not send STP BPDUs on dual-connected links; it only sends BPDUs on single-connected links. The switch in the primary role sends STP BPDUs on all single- and dual-connected links.

Send BPDUsPrimarySecondary
Single-connected linksYesYes
Dual-connected linksYesNo

By default, the role is determined by comparing the MAC addresses of the two sides of the peering link; the switch with the lower MAC address assumes the primary role. You can override this by setting the priority configuration, either by specifying the clagd-priority option in /etc/network/interfaces, or by using clagctl. The switch with the lower priority value is given the primary role; the default value is 32768, and the range is 0 to 65535. Read the clagd(8) and clagctl(8) man pages for more information.

When the clagd service is exited during switch reboot or the service is stopped in the primary switch, the peer switch that is in the secondary role will become primary. If the primary switch goes down without stopping the clagd service for any reason or the peer link goes down, the secondary switch will not change its role. In case the peer switch is determined to be not alive, the switch in the secondary role will roll back the LACP system ID to be the bond interface MAC address instead of the clagd-sys-mac and the switch in primary role uses the clagd-sys-mac as the LACP system ID on the bonds.

Configuring MLAG

Configuring MLAG involves:

  • On the dual-connected devices, create a bond that uses LACP.
  • On each peer switch, configure the interfaces, including bonds, VLANs, bridges and peer links.

MLAG synchronizes the dynamic state between the two peer switches, but it does not synchronize the switch configurations. After modifying the configuration of one peer switch, you must make the same changes to the configuration on the other peer switch. This applies to all configuration changes, including:

  • Port configuration: For example, VLAN membership, MTU, and bonding parameters.
  • Bridge configuration: For example, spanning tree parameters or bridge properties.
  • Static address entries: For example, static FDB entries and static IGMP entries.
  • QoS configuration: For example, ACL entries.

You can verify the configuration of VLAN membership using the clagctl -v verifyvlans command.

Reserved MAC Address Range

In order to prevent MAC address conflicts with other interfaces in the same bridged network, Cumulus Networks has reserved a range of MAC addresses specifically to use with MLAG. This range of MAC addresses is 44:38:39:ff:00:00 to 44:38:39:ff:ff:ff. 

Cumulus Networks recommends you use this range of MAC addresses when configuring MLAG. 

Configuring the Host or Switch

On your dual-connected device, create a bond that uses LACP. The method you use varies with the type of device you are configuring. The following image is a basic MLAG configuration, showing all the essential elements; a more detailed two-leaf/two-spine configuration is below

Configuring the Interfaces

Every interface that connects to the MLAG pair from a dual-connected device should be placed into a bond, even if the bond contains only a single link on a single physical switch (since the MLAG pair contains two or more links). Layer 2 data travels over this bond. In the examples throughout this chapter, peerlink is the name of the bond.

Single-attached hosts, also known as orphan ports, can be just a member of the bridge.

Additionally, the fast mode of LACP should be configured on the bond to allow more timely updates of the LACP state. These bonds will then be placed in a bridge, which will include the peer link between the switches.

In order to enable communication between the clagd services on the peer switches, you should choose an unused VLAN (also known as a switched virtual interface or SVI here) and assign an unrouteable link-local address to give the peer switches layer 3 connectivity between each other. To ensure that the VLAN is completely independent of the bridge and spanning tree forwarding decisions, configure the VLAN as a VLAN subinterface on the peer link bond rather than the VLAN-aware bridge. Cumulus Networks recommends you use 4094 for the peerlink VLAN (peerlink.4094 below) if possible. In addition, to avoid issues with STP, make sure you include untagged traffic on the peer link.

You can also specify a backup interface, which is any layer 3 backup interface for your peer links in the event that the peer link goes down. See below for more information about the backup link.

For example, if peerlink is the inter-chassis bond, and VLAN 4094 is the peerlink VLAN, configure peerlink.4094 using:

auto peerlink.4094
iface peerlink.4094
  address 169.254.1.1/30
  clagd-enable yes
  clagd-peer-ip 169.254.1.2
  clagd-backup-ip 10.0.1.50
  clagd-sys-mac 44:38:39:FF:40:94

Then run ifup on the peerlink VLAN interface. In this example, the command would be sudo ifup peerlink.4094.

There is no need to add VLAN 4094 to the bridge VLAN list, as it is unnecessary there.

Keep in mind that when you change the MLAG configuration in the interfaces file, the changes take effect when you bring the peerlink interface up with ifup. Do not use service clagd restart to apply the new configuration.

Do not use 169.254.0.1 as the MLAG peerlink IP address, as Cumulus Linux uses this address exclusively for  BGP unnumbered interfaces.

Example MLAG Configuration

An example configuration is included below. It configures two bonds for MLAG, each with a single port, a peer link that is a bond with two member ports, and three VLANs on each port. You store the configuration in /etc/network/interfaces on each peer switch.

Configuring these interfaces uses syntax from ifupdown2 and the VLAN-aware bridge driver mode. The bridges use these Cumulus Linux-specific keywords:

  • bridge-vids, which defines the allowed list of tagged 802.1q VLAN IDs for all bridge member interfaces. You can specify non-contiguous ranges with a space-separated list, like
    bridge-vids 100-200 300 400-500.
  • bridge-pvid, which defines the untagged VLAN ID for each port. This is commonly referred to as the native VLAN.

 

The bridge configurations below indicate that each bond carries tagged frames on VLANs 1000 to 3000 but untagged frames on VLAN 1. Also, take note on how you configure the VLAN subinterface used for clagd communication (peerlink.4094 in the sample configuration below).

At minimum, this VLAN subinterface should not be in your Layer 2 domain, and you should give it a very high VLAN ID (up to 4094). Read more about the range of VLAN IDs you can use.

The configuration for the spines should look like the following (note that the clag-id and clagd-sys-mac must be the same for the corresponding bonds on spine1 and spine2):

spine1

 
# The loopback network interface auto lo
iface lo 
inet loopback

# The primary network interface 
auto eth0
iface eth0
    address 10.0.0.1 
    netmask 255.255.255.0
        
auto peerlink 
iface peerlink
    bond-slaves swp31 swp32 
        
auto peerlink.4094 
iface peerlink.4094
    address 169.254.255.1 
    netmask 255.255.255.0      
    clagd-priority 4096
    clagd-peer-ip 169.254.255.2
    clagd-backup-ip 10.0.0.2
    clagd-sys-mac 44:38:39:ff:00:01

# ToR pair #1 
auto downlink1 
iface downlink1
    bond-slaves swp29 swp30 
    clag-id 1
        
# ToR pair #2 
auto downlink2 
iface downlink2
    bond-slaves swp27 swp28 
    clag-id 2
        
auto br
iface br
    bridge-vlan-aware yes
    bridge-ports uplinkA peerlink downlink1 downlink2 
    bridge-stp on
    bridge-vids 1000-2999
    bridge-pvid 1
    bridge-mcsnoop 1

spine2

 
# The loopback network interface auto lo
iface lo 
inet loopback

# The primary network interface 
auto eth0
iface eth0
    address 10.0.0.2 
    netmask 255.255.255.0
        
auto peerlink 
iface peerlink
    bond-slaves swp31 swp32 
        
auto peerlink.4094 
iface peerlink.4094
    address 169.254.255.2 
    netmask 255.255.255.0      
    clagd-priority 8192
    clagd-peer-ip 169.254.255.1
    clagd-backup-ip 10.0.0.1
    clagd-sys-mac 44:38:39:ff:00:01

# ToR pair #1 
auto downlink1 
iface downlink1
    bond-slaves swp29 swp30 
    clag-id 1
        
# ToR pair #2 
auto downlink2 
iface downlink2
    bond-slaves swp27 swp28 
    clag-id 2
        
auto br
iface br
    bridge-vlan-aware yes
    bridge-ports uplinkA peerlink downlink1 downlink2 
    bridge-stp on
    bridge-vids 1000-2999
    bridge-pvid 1
    bridge-mcsnoop 1

Here is an example configuration file for the switches leaf1 and leaf2. Note that the clag-id and clagd-sys-mac must be the same for the corresponding bonds on leaf1 and leaf2:

leaf1

        
# The loopback network interface
auto lo
iface lo inet loopback
        
# The primary network interface
auto eth0
iface eth0
    address 10.0.0.3
    netmask 255.255.255.0
        
auto spine1-2
iface spine1-2
    bond-slaves swp49 swp50
    clag-id 1
        
auto peerlink
iface peerlink
    bond-slaves swp51 swp52
        
auto peerlink.4094
iface peerlink.4094
    address 169.254.255.3
    netmask 255.255.255.0
    clagd-priority 4096
    clagd-peer-ip 169.254.255.4
    clagd-backup-ip 10.0.0.4
    clagd-sys-mac 44:38:39:ff:01:02
  
auto host1
iface host1
    bond-slaves swp1
    clag-id 2
    mstpctl-portadminedge yes
    mstpctl-bpduguard yes
  
auto host2
iface host2
    bond-slaves swp2
    clag-id 3
    mstpctl-portadminedge yes
    mstpctl-bpduguard yes


auto br0
iface br0
   bridge-vlan-aware yes
   bridge-ports spine1-2 peerlink host1 host2
   bridge-stp on
   bridge-vids 1000-2999
   bridge-pvid 1

leaf2

        
# The loopback network interface
auto lo
iface lo inet loopback
        
# The primary network interface
auto eth0
iface eth0
    address 10.0.0.4
    netmask 255.255.255.0
        
auto spine1-2
iface spine1-2
    bond-slaves swp49 swp50
    clag-id 1
        
auto peerlink
iface peerlink
    bond-slaves swp51 swp52
        
auto peerlink.4094
iface peerlink.4094
    address 169.254.255.4
    netmask 255.255.255.0
    clagd-priority 8192
    clagd-peer-ip 169.254.255.3
    clagd-backup-ip 10.0.0.3
    clagd-sys-mac 44:38:39:ff:01:02
  
auto host1
iface host1
    bond-slaves swp1
    clag-id 2
    mstpctl-portadminedge yes
    mstpctl-bpduguard yes
  
auto host2
iface host2
    bond-slaves swp2
    clag-id 3
    mstpctl-portadminedge yes
    mstpctl-bpduguard yes


auto br0
iface br0
   bridge-vlan-aware yes
   bridge-ports spine1-2 peerlink host1 host2
   bridge-stp on
   bridge-vids 1000-2999
   bridge-pvid 1

The configuration is almost identical, except for the IP addresses used for managing the clagd service.

In the configurations above, the clagd-peer-ip and clagd-sys-mac parameters are mandatory, while the rest are optional. When mandatory clagd commands are present under a peer link subinterface, by default clagd-enable is treated as yes; to disable clagd on the subinterface, set clagd-enable to no. Use clagd-priority to set the role of the MLAG peer switch to primary or secondary. Each peer switch in an MLAG pair must have the same clagd-sys-mac setting. Each clagd-sys-mac setting should be unique to each MLAG pair in the network. For more details refer to man clagd.

Configuring MLAG with a Traditional Mode Bridge

It's possible to configure MLAG with a bridge in traditional mode instead of VLAN-aware mode. In order to do so, the peer link and all dual-connected links must be configured as untagged/native ports on a bridge (note the absence of any VLANs in the bridge-ports line and the lack of the bridge-vlan-aware parameter below):

auto br
iface br
  bridge-ports peerlink spine1-2 host1 host2

Because you can have multiple bridges in traditional mode, you can create more than one bridge on the switch, in case you need to use tagged VLANs, as the following example shows:

#native vlan (default vlan1)
auto bridge
iface bridge
  bridge-ports peerlink host1 host2 host3
  bridge-stp on

# also can configure additional tagged birdges
auto bridge1000
iface bridge1000
  bridge-ports peerlink.1000 host1.1000 host2.1000 host3.1000
  bridge-stp on

For a deeper comparison of traditional versus VLAN-aware bridge modes, read this knowledge base article.

Using the clagd Command Line Interface

A command line utility called clagctl is available for interacting with a running clagd service to get status or alter operational behavior. For detailed explanation of the utility, please refer to the clagctl(8)man page. The following is a sample output of the MLAG operational status displayed by the utility:

cumulus@switch$ clagctl
The peer is alive
     Our Priority, ID, and Role: 8192 00:e0:ec:26:50:89 primary
    Peer Priority, ID, and Role: 8192 00:e0:ec:27:49:f6 secondary
          Peer Interface and IP: peerlink.4094 169.254.255.2
                     System MAC: 44:38:39:ff:00:01

                         Dual Attached Ports
      Our Interface      Peer Interface     CLAG Id
      ----------------   ----------------   -------
             downlink1   downlink1          1
             downlink2   downlink2          2

Peer Link Interfaces and the protodown State

In addition to the standard UP and DOWN administrative states, an interface that is a member of an MLAG bond can also be in a protodown state. When MLAG detects a problem that could result in connectivity issues such as traffic black-holing or a network meltdown if the link carrier was left in an UP state, it can put that interface into protodown state. Such connectivity issues include:

  • When the peer link goes down but the peer switch is up (that is, the backup link is active).
  • When the bond is configured with an MLAG ID, but the clagd service is not running (whether it was deliberately stopped or simply died).
  • When an MLAG-enabled node is booted or rebooted, the MLAG bonds are placed in a protodown state until the node establishes a connection to its peer switch, or five minutes have elapsed.

When an interface goes into a protodown state, it results in a local OPER DOWN (carrier down) on the interface. As of Cumulus Linux 2.5.5, the protodown state can be manipulated with the ip link set command. Given its use in preventing network meltdowns, manually manipulating protodown is not recommended outside the scope of interaction with the Cumulus Networks support team.

The following ip link show command output shows an interface in protodown state. Notice that the link carrier is down (NO-CARRIER):

cumulus@switch:~$ ip link show swp1
3: swp1: <NO-CARRIER,BROADCAST,MULTICAST,SLAVE,UP> mtu 1500 qdisc pfifo_fast master host-bond1 state DOWN mode DEFAULT qlen 500 protodown on
   link/ether 44:38:39:00:69:84 brd ff:ff:ff:ff:ff:ff

You can specify a backup link for your peer links in the event that the peer link goes down. When this happens, the clagd service uses the backup link to check the health of the peer switch. To configure this, edit /etc/network/interfaces and add clag-backup-ip <ADDRESS> to the peer link configuration.

However, if the eth0 management interface is enabled on a switch with an MLAG configuration, you cannot specify a backup link over the switch ports. The backup link uses eth0 if a management VRF is configured.

Here's an example:

auto peerlink.4094
iface peerlink.4094
    address 169.254.255.1
    netmask 255.255.255.0
    clagd-enable yes
    clagd-priority 8192
    clagd-peer-ip 169.254.255.2
    clagd-backup-ip 10.0.1.50
    clagd-sys-mac 44:38:39:ff:00:01
    clagd-args --priority 1000

The backup IP address must be different than the peer link IP address (clagd-peer-ip above), and it must be reachable by a route that doesn't use the peer link.

Cumulus Networks recommends you use the switch's management IP address for this purpose.

You can also specify the backup UDP port. The port defaults to 5342, but you can configure it as an argument in clagd-args using --backupPort <PORT>.

auto peerlink.4094
iface peerlink.4094
    address 169.254.255.1
    netmask 255.255.255.0
    clagd-enable yes
    clagd-priority 8192
    clagd-peer-ip 169.254.255.2
    clagd-backup-ip 10.0.1.50
    clagd-sys-mac 44:38:39:ff:00:01
    clagd-args --backupPort 5400

You can see the backup IP address if you run clagctl:

cumulus@switch$ clagctl
The peer is alive
     Our Priority, ID, and Role: 8192 00:e0:ec:26:50:89 primary
    Peer Priority, ID, and Role: 8192 00:e0:ec:27:49:f6 secondary
          Peer Interface and IP: peerlink.4094 169.254.255.2
                      Backup IP: 10.0.1.50
                     System MAC: 44:38:39:ff:00:01

                         Dual Attached Ports
      Our Interface      Peer Interface     CLAG Id
      ----------------   ----------------   -------
             downlink1   downlink1          1
             downlink2   downlink2          2 

Monitoring Dual-Connected Peers

Upon receipt of a valid message from its peer, the switch knows that clagd is alive and executing on that peer. This causes clagd to change the system ID of each bond that was assigned a clag-id from the default value (the MAC address of the bond) to the system ID assigned to both peer switches. This makes the hosts connected to each switch act as if they are connected to the same system so that they will use all ports within their bond. Additionally, clagd determines which bonds are dual-connected and modifies the forwarding and learning behavior to accommodate these dual-connected bonds.

If the peer does not receive any messages for three update intervals, then that peer switch is assumed to no longer be acting as an MLAG peer. In this case, the switch reverts all configuration changes so that it operates as a standard non-MLAG switch. This includes removing all statically assigned MAC addresses, clearing the egress forwarding mask, and allowing addresses to move from any port to the peer port. Once a message is again received from the peer, MLAG operation starts again as described earlier. You can configure a custom timeout setting by adding  --peerTimeout <VALUE> to clagd-args in /etc/network/interfaces.

Once bonds are identified as dual-connected, clagd sends more information to the peer switch for those bonds. The MAC addresses (and VLANs) that have been dynamically learned on those ports are sent along with the LACP partner MAC address for each bond. When a switch receives MAC address information from its peer, it adds MAC address entries on the corresponding ports. As the switch learns and ages out MAC addresses, it informs the peer switch of these changes to its MAC address table so that the peer can keep its table synchronized. Periodically, at 45% of the bridge ageing time, a switch will send its entire MAC address table to the peer, so that peer switch can verify that its MAC address table is properly synchronized.

The switch sends an update frequency value in the messages to its peer, which tells clagd how often the peer will send these messages. You can configure a different frequency by adding --lacpPoll <SECONDS> to clagd-args in /etc/network/interfaces.

In this scenario, the spine switches connect at layer 3, as shown in the image below. Alternatively, the spine switches can be singly connected to each core switch at layer 3 (not shown below).

 

In this design, the spine switches route traffic between the server hosts in the layer 2 domains and the core. The servers (host1 - host4) each have a layer 2 connection up to the spine layer where the default gateway for the host subnets resides. However, since the spine switches as gateway devices communicate at layer 3, you need to configure a protocol such as VRR (Virtual Router Redundancy) between the spine switch pair to support active/active forwarding.

Then, to connect the spine switches to the core switches, you need to determine whether the routing is static or dynamic. If it's dynamic, you must choose which protocol — OSPF or BGP — to use. When enabling a routing protocol in an MLAG environment it is also necessary to manage the uplinks, because by default MLAG is not aware of layer 3 uplink interfaces. In the event of a peerlink failure MLAG does not remove static routes or bring down a BGP or OSPF adjacency unless a separate link state daemon such as ifplugd is used. 

IGMP Snooping with MLAG

IGMP snooping processes IGMP reports received on a bridge port in a bridge to identify hosts that are configured to receive multicast traffic destined to that group. An IGMP query message received on a port is used to identify the port that is connected to a router and configured to receive multicast traffic.

IGMP snooping is enabled by default on the bridge. IGMP snooping multicast database entries and router port entries are synced to the peer MLAG switch. If there is no multicast router in the VLAN, the IGMP querier can be configured on the switch to generate IGMP query messages by adding a configuration like the following to /etc/network/interfaces:

auto br.100
vlan br.100 #igmp snooping is enabled by default, but is shown here for completeness bridge-mcsnoop 1 # If you need to specify the querier IP address bridge-igmp-querier-src 123.1.1.1

To display multicast group and router port information, use the bridge -d mdb show command:

cumulus@switch:~# sudo bridge -d mdb show
dev br port bond0 vlan 100 grp 234.1.1.1 temp
router ports on br: bond0
 Runtime Configuration (Advanced)
cumulus@switch:~# sudo brctl setmcqv4src br 100 123.1.1.1
cumulus@switch:~# sudo brctl setmcquerier br 1
cumulus@switch:~# sudo brctl showmcqv4src br

vlan            querier address
100             123.1.1.1

Monitoring the Status of the clagd Service

Due to the critical nature of the clagd service, an external process, called jdoo, continuously monitors the status of clagd. If the clagd service dies or becomes unresponsive for any reason, the  jdoo process will get clagd up and running again. This monitoring is automatically configured and enabled as long as clagd is enabled (that is, clagd-peer-ip and clagd-sys-mac are configured in /etc/network/interfaces) and clagd been started. When clagd is explicitly stopped, for example with the service clagd stop command, monitoring of clagd is also stopped.

The jdoo process checks two things to make sure the clagd service is operating properly:

  • The result of the service clagd status command. If the command returns that clagd is running, or that clagd is not configured to run, then jdoo does nothing. If service clagd status returns that clagd is not running but was configured to run, jdoo will start the clagd service. This check is performed every 30 seconds. Due to the way the jdoo process implements this check, it may start the clagd process twice. This is harmless, since clagd checks to make sure another instance is not already running when it begins executing. This is indicated with a message in the clagd log file, /var/log/clagd.log.
  • The modification time of the /var/run/clagd.alive file. As clagd runs, it periodically updates the modification time of the /var/run/clagd.alive file (by default, every 4 seconds). If jdoo notices that this file's modification time has not been updated within the last 4 minutes, it will assume clagd is alive, but hung, and will restart clagd. If clagd is not enabled to run, this check still occurs and jdoo will start clagd. But since clagd is not configured to run, nothing will happen except that a message is written to the jdoo log file that it tried to start clagd.

You can check the status of clagd monitoring by using the jdoo summary command:

cumulus@switch:~$ sudo jdoo summary
The jdoo daemon 5.4 uptime: 15m
...
Program 'clagd'                     Status ok
File 'clagd.alive'                  Waiting
...

MLAG Best Practices

For MLAG to function properly, the dual-connected hosts' interfaces should be configured identically on the pair of peering switches. See the note above in the Configuring MLAG section.

Understanding MTU in an MLAG Configuration

Note that the MTU in MLAG traffic is determined by the bridge MTU. Bridge MTU is determined by the lowest MTU setting of an interface that is a member of the bridge. If an MTU other than the default of 1500 bytes is desired, you must configure the MTU on each physical interface and bond interface that are members of the MLAG bridges in the entire bridged domain.

For example, if an MTU of 9216 is desired through the MLAG domain in the example shown above:

On the the leaf switches, configure mtu 9216  for each of following interfaces, since they are members of bridge br0: spine1-2, peerlink, host1, host2.

auto br0
iface br0
   bridge-vlan-aware yes
   bridge-ports spine1-2 peerlink host1 host2   <- List of bridge member interfaces
   ...

Likewise, to ensure the MTU 9216 path is respected through the spine switches above, also change the MTU setting for bridge br by configuring mtu 9216 for each of the following members of bridge br on spine1 and spine2: uplinkA, peerlink, downlink1, downlink2.

auto br
iface br
    bridge-vlan-aware yes
    bridge-ports uplinkA peerlink downlink1 downlink2 
    ...

STP Interoperability with MLAG

Cumulus Networks recommends that you always enable STP in your layer 2 network.

Further, with MLAG, Cumulus Networks recommends you enable BPDU guard on the host-facing bond interfaces. (For more information about BPDU guard, see BPDU Guard and Bridge Assurance.)

Debugging STP with MLAG

/var/log/daemon.log has mstpd logs.

Run mstpctl debuglevel 3 to see MLAG-related logs in /var/log/daemon.log:

cumulus@switch:~$ sudo mstpctl showportdetail br peer-bond
br:peer-bond CIST info
  enabled            yes                     role                 Designated
  port id            8.008                   state                forwarding
  ...............
  bpdufilter port    no                     
  clag ISL           yes                     clag ISL Oper UP     yes
  clag role          primary                 clag dual conn mac   0:0:0:0:0:0
  clag remote portID F.FFF                   clag system mac      44:38:39:ff:0:1
cumulus@switch:~$ 

cumulus@switch:~$ sudo mstpctl showportdetail br downlink-1
br:downlink-1 CIST info
  enabled            yes                     role                 Designated
  port id            8.006                   state                forwarding
  ..............
  bpdufilter port    no                     
  clag ISL           no                      clag ISL Oper UP     no
  clag role          primary                 clag dual conn mac   0:0:0:3:11:1
  clag remote portID F.FFF                   clag system mac      44:38:39:ff:0:1
cumulus@switch:~$

Best Practices for STP with MLAG

  • The STP global configuration must be the same on both the switches.
  • The STP configuration for dual-connected ports should be the same on both peer switches.
  • Use mstpctl commands for all spanning tree configurations, including bridge priority, path cost and so forth. Do not use brctl commands for spanning tree, except for brctl stp on/off, as changes are not reflected to mstpd and can create conflicts.

Troubleshooting MLAG

By default, when clagd is running, it logs its status to the /var/log/clagd.log file and syslog. Example log file output is below:

Jan 14 23:45:10 switch clagd[3704]: Beginning execution of clagd version 1.0.0
Jan 14 23:45:10 switch clagd[3704]: Invoked with: /usr/sbin/clagd --daemon 169.254.2.2 peer-bond.4000 44:38:39:ff:00:01 --priority 8192
Jan 14 23:45:11 switch clagd[3995]: Role is now secondary
Jan 14 23:45:31 switch clagd[3995]: Role is now primary
Jan 14 23:45:32 switch clagd[3995]: The peer switch is active.
Jan 14 23:45:35 switch clagd[3995]: downlink-1 is now dual connected.

Understanding STP and LACP Behavior when MLAG Fails

For an in-depth look at how LACP and STP react during a number of failure scenarios, read this knowledge base article.

Caveats and Errata

If both the backup and peer connectivity are lost within a 30-second window, the switch in the secondary role misinterprets the event sequence, believing the peer switch is down, so it takes over as the primary.

Configuration Files