Switch Port Attributes

This chapter discusses the various network interfaces on a switch running Cumulus Linux, how to configure various interface-level settings (if needed) and some troubleshooting commands.

Interface Types

Cumulus Linux exposes network interfaces for several types of physical and logical devices:

  • lo, network loopback device

  • ethN, switch management port(s), for out of band management only

  • swpN, switch front panel ports

  • (optional) brN, bridges (IEEE 802.1Q VLANs)

  • (optional) bondN, bonds (IEEE 802.3ad link aggregation trunks, or port channels)

Interface Settings

Each physical network interface has a number of configurable settings:

Almost all of these settings are configured automatically for you, depending upon your switch ASIC, although you must always set MTU manually.

You can only set MTU for logical interfaces. If you try to set auto-negotiation, duplex mode or link speed for a logical interface, an unsupported error gets returned.

Differences between Broadcom-based and Mellanox-based Switches

On a Broadcom-based switch, all you need to do is enable auto-negotiation. Once enabled, Cumulus Linux automatically configures the link speed, duplex mode and forward error correction (FEC, if the cable or optic requires it) for every switch port, based on the port type and cable or optic used on the port, as listed in the table below.

Ports are always automatically configured on a Mellanox-based switch, with one exception - you only need to configure is MTU. You don’t even need to enable auto-negotation, as the Mellanox firmware configures everything for you.

Enabling Auto-negotiation

To configure auto-negotiation for a Broadcom-based switch, set link-autoneg to on for all the switch ports. For example, to enable auto-negotiation for swp1 through swp52:

cumulus@switch:~$ net add interface swp1-52 link autoneg on
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit

Any time you enable auto-negotiation, Cumulus Linux restores the default configuration settings specified in the table below.

By default on a Broadcom-based switch, auto-negotiation is disabled - except on 10G and 1000BASE-T switch ports, where it’s required for links to work at all. And for RJ-45 SFP adapters, you need to manually configure the settings as described in the default settings table below.

If you disable it later or never enable it, then you have to configure the duplex, FEC and link speed settings manually using NCLU

  • see the relevant sections below. The default speed if you disable auto-negotiation depends on the type of connector used with the port. For example, a QSFP28 optic defaults to 100G, while a QSFP+ optic defaults to 40G and SFP+ defaults to 10G.

You should keep auto-negotiation enabled at all times. If you do decide to disable it, keep in mind the following:

  • You must manually set link speed, duplex, pause and FEC.
  • Disabling auto-negotiation on a copper cable of any kind prevents the port from optimizing the link through link training.
  • Disabling auto-negotiation on a 1G optical cable prevents detection of single fiber breaks.
  • You cannot disable auto-negotiation for 1GT or 10GT cables.

However, 10/100/1000BASE-T RJ-45 SFP adapters do not work with auto-negotiation enabled. You must manually configure these ports using the settings below (link-autoneg=off, link-speed=1000|100|10, link-duplex=full|half).

Depending upon the connector used for a port, enabling auto-negotiation also enables forward error correction (FEC), if the cable requires it (see the table below). FEC always adjusts for the speed of the cable. However, you cannot disable FEC separately using NCLU.

Port Speed and Duplexing

Cumulus Linux supports both half- and full-duplex configurations. Supported port speeds include 100M, 1G, 10G, 25G, 40G, 50G and 100G. If you need to manually set the speed on a Broadcom-based switch, set it in terms of Mbps, where the setting for 1G is 1000, 40G is 40000 and 100G is 100000, for example.

The duplex mode setting defaults to full. You only need to specify link duplex if you want half-duplex mode.

Example Port Speed and Duplexing Configuration

The following NCLU commands configure the port speed for the swp1 interface:

cumulus@switch:~$ net add interface swp1 link speed 10000
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit

The above commands create the following /etc/network/interfaces code snippet:

auto swp1
iface swp1
   link-speed 10000

Port Speed Limitations

Ports can be configured to one speed less than their maximum speed.

Switch Port TypeLowest Configurable Speed
1G100 Mb
10G1 Gigabit (1000 Mb)
40G10G*
100G50G & 40G (with or without breakout port), 25G*, 10G*

*Requires the port to be converted into a breakout port. See below.

On Dell S4148F-ON and S4128F-ON switches, you must configure ports within the same port group with the same link speed.

MTU

Interface MTU (maximum transmission unit) applies to traffic traversing the management port, front panel/switch ports, bridge, VLAN subinterfaces and bonds - in other words, both physical and logical interfaces.

MTU is the only interface setting that must be set manually.

In Cumulus Linux, ifupdown2 assigns 1500 as the default MTU setting. To change the setting, run:

cumulus@switch:~$ net add interface swp1 mtu 9000
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit

Some switches may not support the same maximum MTU setting in hardware for both the management interface (eth0) and the data plane ports.

MTU for a Bridge

The MTU setting is the lowest MTU setting of any interface that is a member of that bridge (that is, every interface specified in bridge-ports in the bridge configuration in the interfaces file), even if another bridge member has a higher MTU value. There is no need to specify an MTU on the bridge. Consider this bridge configuration:

auto bridge
iface bridge
    bridge-ports bond1 bond2 bond3 bond4 peer5
    bridge-vids 100-110
    bridge-vlan-aware yes

In order for bridge to have an MTU of 9000, set the MTU for each of the member interfaces (bond1 to bond 4, and peer5), to 9000 at minimum.

Use MTU 9216 for a bridge

Two common MTUs for jumbo frames are 9216 and 9000 bytes. The corresponding MTUs for the VNIs would be 9166 and 8950.

When configuring MTU for a bond, configure the MTU value directly under the bond interface; the configured value is inherited by member links/slave interfaces. If you need a different MTU on the bond, set it on the bond interface, as this ensures the slave interfaces pick it up. There is no need to specify MTU on the slave interfaces.

VLAN interfaces inherit their MTU settings from their physical devices or their lower interface; for example, swp1.100 inherits its MTU setting from swp1. Hence, specifying an MTU on swp1 ensures that swp1.100 inherits swp1’s MTU setting.

If you are working with VXLANs, the MTU for a virtual network interface (VNI) must be 50 bytes smaller than the MTU of the physical interfaces on the switch, as those 50 bytes are required for various headers and other data. You should also consider setting the MTU much higher than the default 1500.

Example MTU Configuration

In general, the policy file specified above handles default MTU settings for all interfaces on the switch. If you need to configure a different MTU setting for a subset of interfaces, use NCLU.

The following commands configure an MTU minimum value of 9000 on swp1:

cumulus@switch:~$ net add interface swp1 mtu 9000
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit

These commands create the following code snippet:

auto swp1
iface swp1
   mtu 9000

You must take care to ensure there are no MTU mismatches in the conversation path. MTU mismatches will result in dropped or truncated packets, degrading or blocking network performance.

The MTU for an SVI interface, such as vlan100, is derived from the bridge. When you use NCLU to change the MTU for an SVI and the MTU setting is higher than it is for the other bridge member interfaces, the MTU for all bridge member interfaces changes to the new setting. If you need to use a mixed MTU configuration for SVIs, for example, if some SVIs have a higher MTU and some lower, then set the MTU for all member interfaces to the maximum value, then set the MTU on the specific SVIs that need to run at a lower MTU.

To view the MTU setting, use net show interface <interface>:

cumulus@switch:~$ net show interface swp1
    Name    MAC                Speed      MTU  Mode
--  ------  -----------------  -------  -----  ---------
UP  swp1    44:38:39:00:00:04  1G        1500  Access/L2

Bringing Down an Interface for a Bridge Member

When you bring down an interface for a bridge member, the MTU for the interface and the MTU for the bridge are both set to the default value of 1500. To work around this, run ifdown on the interface, then run the sudo ip link set dev <interface> mtu <mtu> command.

For example:

sudo ifdown swp3
sudo ip link set dev swp3 mtu 9192

As an alternative, add a post-down command in the /etc/network/interfaces file to reset the MTU of the interface. For example:

auto swp3
iface swp3
    alias BNBYLAB-PD01HV-01_Port3
    bridge-vids 106 109 119 141 150-151
    mtu 9192
    post-down /sbin/ip link set dev swp3 mtu 9192

Setting a Policy for Global System MTU

For a global policy to set MTU, create a policy document (called mtu.json here) like the following:

cat /etc/network/ifupdown2/policy.d/mtu.json
{
 "address": {"defaults": { "mtu": "9216" }
            }
}

If your platform does not support a high MTU on eth0, you can set a lower MTU with the following command:

cumulus@switch:~$ net add interface eth0 mtu 1500
cumulus@switch:~$ net commit

The policies and attributes in any file in /etc/network/ifupdown2/policy.d/ override the default policies and attributes in /var/lib/ifupdown2/policy.d/.

FEC

Forward Error Correction (FEC) is an encoding and decoding layer that enables the switch to detect and correct bit errors introduced over the cable between two interfaces. Because 25G transmission speeds can introduce a higher than acceptable bit error rate (BER) on a link, FEC is required or recommended for 25G, 4x25G, and 100G link speeds.
The two interfaces on each end must use the same FEC setting for the link to come up.

There is a very small latency overhead required for FEC. For most applications, this small amount of latency is preferable to error packet retransmission latency.

There are two FEC types:

  • Reed Solomon (RS), IEEE 802.3 Clause 108 (CL108) on individual 25G channels and Clause 91 on 100G (4channels). This is the highest FEC algorithm, providing the best bit-error correction.
  • Base-R (BaseR), Fire Code (FC), IEEE 802.3 Clause 74 (CL74). Base-R provides less protection from bit errors than RS FEC but adds less latency.

There are additional FEC options for Cumulus Linux configuration:

  • Auto FEC instructs the hardware to select the best FEC. For Copper DAC, FEC can be negotiated with the remote end. However, optical modules do not have auto-negotiation capability; if the device chooses a preferred mode, it might not match the remote end.
  • No FEC (no error correction is done). This is the current default on a Broadcom switch.

Important

The Tomahawk switch does not support RS FEC or auto-negotiation of FEC on 25G lanes that are broken out (Tomahawk pre-dates 802.3by). If you are using a 4x25G breakout DAC or AOC on a Tomahawk switch, you can configure either Base-R FEC or no FEC, and choose cables appropriate for that limitation (CA-25G-S, CA-25G-N or fiber).

Tomahawk+ and Maverick switches do not have this limitation.

For 25G DAC, 4x25G Breakouts DAC and 100G DAC cables, the IEEE 802.3by specification creates 3 classes:

  • CA-25G-L (long cables - achievable cable length of at least 5m) dB loss less or equal to 22.48. Requires RS FEC and expects BER of 10-5 or better with RS FEC enabled.
  • CA-25G-S (short cables - achievable cable length of at least 3m) dB loss less or equal to 16.48. Requires Base-R FEC and expects BER of 10-8 or better with Base-R FEC enabled.
  • CA-25G-N (no FEC - achievable cable length of at least 3m) dB loss less or equal to 12.98. Does not require FEC. Expects BER 10-12 or better with no FEC.

The IEEE classification is based on various dB loss measurements and minimum achievable cable length. You can build longer and shorter cables if they comply to the dB loss and BER requirements.

If a cable is manufactured to CA-25G-S classification and FEC is not enabled, the BER might be unacceptable in a production network. It is important to set the FEC according to the cable class (or better) to have acceptable bit error rates. See Determining Cable Class below.

You can check bit errors using cl-netstat (RX_ERR column) or ethtool -S (HwIfInErrors counter) after a large amount of traffic has passed through the link. A non zero value indicates bit errors. Expect error packets to be zero or extremely low compared to good packets. If a cable has an unacceptable rate of errors with FEC enabled, replace the cable.

For 25G, 4x25G Breakout, and 100G Fiber modules and AOCs, there is no classification of 25G cable types for dB loss, BER, or Length. FEC is recommended but might not be required if the BER is low enough.

Determining Cable Class

You can determine the cable class from the Extended Specification Compliance Code field (SFP28: 0Ah, byte 35, QSFP28: Page 0, byte 192) in the cable EEPROM programming.

For 100G DAC, most manufacturers use the 0x0Bh 100GBASE-CR4 or 25GBASE-CR CA-L value (the 100G DAC specification predates the IEEE 802.3by 25G DAC specification). RS FEC is the expected setting for 100G DAC but might not be required with shorter or better cables.

A manufacturer’s EEPROM setting might not match the dB loss on a cable or the actual bit error rates that a particular cable introduces. Use the designation as a guide, but set FEC according to the bit error rate tolerance in the design criteria for the network. For most applications, the highest mutual FEC ability of both end devices is the best choice.

You can determine for which grade the manufacturer has designated the cable as follows.

For the SFP28 DAC, run the following command:

root@mlx-2410-02:~# ethtool -m swp35 hex on | grep 0020 | awk '{ print $6}'
0c

The values at location 0x0024 are:

  • 0x0b : CA-L (long cable - RS FEC required)
  • 0x0c : CA-S (short cable - BaseR or better FEC required)
  • 0x0d : CA-N (no FEC required)

For the QSFP28 DAC, run the following command:

root@mlx-2410-02:~# ethtool -m swp51s0 hex on | grep 00c0 | awk '{print $2}'
0b

The values at 0x00c0 are:

  • 0x0b : CA-L (long cable - RS FEC required) or 100G CR4
  • 0x0c : CA-S (short cable - BaseR or better FEC required)
  • 0x0d : CA-N (no FEC required)

Cable Class Examples

In each example below, the Compliance field is derived using the method described above and is not visible in the ethool -m output.

Example 1: 3meter cable that does not require FEC (CA-N)
Cost : More expensive
Cable size : 26AWG (Note that AWG does not necessarily correspond to overall dB loss or BER performance)
Compliance Code : 25GBASE-CR CA-N

Example 2: 3meter cable that requires Base-R FEC (CA-S)
Cost: Less expensive
Cable size : 26AWG
Compliance Code : 25GBASE-CR CA-S

When in doubt, consult the manufacturer directly to determine the cable classification.

How Does Cumulus Linux use FEC?

The Mellanox switch enables FEC automatically first. The port firmware tries a pre-set list of link configuration combinations to attempt to bring up the link. It is possible to get a link up to a Mellanox switch without enabling FEC on the remote device as the switch eventually finds a working combination to the neighbor without FEC.

On a Broadcom switch, Cumulus Linux does not enable FEC by default. Cumulus Networks recommends you configure FEC explicitly. On 100G DACs, you can configure link-autoneg so that the port attempts to negotiate FEC settings with the remote peer.

The following sections describe how to display the current FEC configuration, and enable and disable FEC on a Broadcom switch.

Displaying the Current FEC Mode

To display the FEC mode currently enabled on a Broadcom switch, run the following command:

cumulus@switch:~# sudo ethtool --show-fec swp23
FEC parameters for swp23:
FEC encodings : None

On a Mellanox switch, the currently-enabled FEC mode is not accessible with user commands at this time; however, you can deduce the mode from the remote FEC setting when the link is up.

Enabling FEC

To enable Reed Solomon (RS) FEC on a link, run the following NCLU commands:

cumulus@switch:~# sudo net add interface swp23 link fec rs
cumulus@switch:~# sudo net commit

To review the FEC setting on the link, run the following command:

cumulus@switch:~# sudo ethtool --show-fec swp23
FEC parameters for swp23:
FEC encodings : RS

To enable Base-R/FireCode FEC on a link, run the following NCLU commands:

cumulus@switch:~# sudo net add interface swp23 link fec baser
cumulus@switch:~# sudo net commit

To review the FEC setting on the link, run the following command:

cumulus@switch:~# sudo ethtool --show-fec swp23
FEC parameters for swp23:
FEC encodings : BaseR

Enabling FEC with Auto-negotiation

FEC with auto-negotiation is supported on DACs only.

To enable FEC with auto-negotiation, run the following NCLU commands:

cumulus@switch:~# sudo net add interface swp12 link autoneg on
cumulus@switch:~# sudo net commit

To view the FEC and auto-negotiation settings, run the following command:

cumulus@switch:~# sudo ethtool swp12 | egrep 'FEC|auto'
Supports auto-negotiation: Yes
Supported FEC modes: RS
Advertised auto-negotiation: Yes
Advertised FEC modes: RS
Link partner advertised auto-negotiation: Yes
Link partner advertised FEC modes: Not reported

cumulus@switch:~# sudo ethtool --show-fec swp12
FEC parameters for swp12:
FEC encodings : RS

Disabling FEC

To disable FEC on a link, run the following NCLU commands:

cumulus@switch:~# sudo net add interface swp23 link fec off
cumulus@switch:~# sudo net commit

To review the FEC setting on the link, run the following command:

cumulus@switch:~# sudo ethtool --show-fec swp23
FEC parameters for swp23:
FEC encodings : None

Interface Configuration Recommendations

The default configuration for each type of interface is described in the following table. Except as noted below, the settings for both sides of the link are expected to be the same.

If the other side of the link is running a version of Cumulus Linux earlier than 3.2, depending up on the interface type, auto-negotiation may not work on that switch. Cumulus Networks recommends you use the default settings on this switch in this case.

Speed

Auto-negotiation

FEC Setting

Manual Configuration Steps

Notes

10/100BASE-T
(RJ-45 SFP adapter)

On

N/A (does not apply at this speed)

$ net add interface swp1 link speed 100
$ net add interface swp1 link autoneg off
auto swp1
iface swp1
  link-autoneg off
  link-speed 100
  • The module has two sets of electronics - the port side, which communicates to the switch ASIC, and the RJ-45 adapter side.

  • Auto-negotiation is always used on the RJ-45 adapter side of the link by the PHY built into the module. This is independent of the switch setting. Set link-autoneg to off.

  • Auto-negotiation needs to be enabled on the server side in this scenario.

10/100BASE-T on a 1G fixed copper port

On

N/A

$ net add interface swp1 link speed 100
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 100
  • 10M or 100M speeds are possible with auto-negotiation OFF on both sides. Testing on an Edgecore AS4610-54P revealed the ASIC reporting auto-negotiation as ON.

  • Power over Ethernet may require auto-negotiation to be ON.

1000BASE-T
(RJ-45 SFP adapter)

On

N/A

$ net add interface swp1 link speed 1000
$ net add interface swp1 link autoneg off
auto swp1
iface swp1
  link-autoneg off
  link-speed 1000
  • The module has two sets of electronics - the port side, which communicates to the switch ASIC, and the RJ-45 side.

  • Auto-negotiation is always used on the RJ-45 side of the link by the PHY built into the module. This is independent of the switch setting. Set link-autoneg to off.

  • Auto-negotiation needs to be enabled on the server side.

1000BASE-T on a 1G fixed copper port

On

N/A

$ net add interface swp1 link speed 1000
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 1000

1000BASE-T on a 10G fixed copper port

On

N/A

$ net add interface swp1 link speed 1000
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 1000

1000BASE-SX,
1000BASE-LX,
1000BASE-CX
(1G Fiber)

Recommended On

N/A

$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  • Without auto-negotiation, the link stays up when there is a single fiber break.

10GBASE-T fixed copper port

On

N/A

$ net add interface swp1 link speed 10000
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 10000

10GBASE-CR,
10GBASE-LR,
10GBASE-SR,
10G AOC

Off

N/A

$ net add interface swp1 link speed 10000
$ net add interface swp1 link autoneg off
auto swp1
iface swp1
  link-autoneg off
  link-speed 10000

40GBASE-CR4

Recommended On

Disable it

$ net add interface swp1 link speed 40000
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 40000
  • 40G standards mandate auto-negotiation should be enabled for DAC connections.

40GBASE-SR4,
40GBASE-LR4,
40G AOC

Off

Disable it

$ net add interface swp1 link speed 40000
$ net add interface swp1 link autoneg off
auto swp1
iface swp1
  link-autoneg off
  link-speed 40000

100GBASE-CR4

On

auto-negotiated

$ net add interface swp1 link speed 100000
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 100000

100GBASE-SR4,
100G AOC

Off

RS

$ net add interface swp1 link speed 100000
$ net add interface swp1 link autoneg off
$ net add interface swp1 link fec rs
auto swp1
iface swp1
  link-autoneg off
  link-speed 100000
  link-fec rs

100GBASE-LR4

Off

None stated

$ net add interface swp1 link speed 100000
$ net add interface swp1 link autoneg off
$ net add interface swp1 link fec off
auto swp1
iface swp1
  link-autoneg off
  link-speed 100000
  link-fec off

25GBASE-CR

On

auto-negotiated*

$ net add interface swp1 link speed 25000
$ net add interface swp1 link autoneg on
auto swp1
iface swp1
  link-autoneg on
  link-speed 25000

25GBASE-SR

Off

RS*

$ net add interface swp1 link speed 25000
$ net add interface swp1 link autoneg off
$ net add interface swp1 link fec baser
auto swp1
iface swp1
  link-autoneg off
  link-speed 25000
  link-fec baser
  • Tomahawk cannot do RS on a single channel, only BASE-R/FC/FireCode/Type74, which violates the 802.3by specification for 25G.

25GBASE-LR

Off

None stated

$ net add interface swp1 link speed 25000
$ net add interface swp1 link autoneg off
$ net add interface swp1 link fec off
auto swp1
iface swp1
  link-autoneg off
  link-speed 25000
  link-fec off

Creating a Default Policy for Various Interface Settings

Instead of configuring these settings for each individual interface, you can specify a policy for all interfaces on a switch, or tailor custom settings for each interface. Create a file in /etc/network/ifupdown2/policy.d/, like in the following example (called address.json), and populate the settings accordingly:

cumulus@switch:~$ cat /etc/network/ifupdown2/policy.d/address.json
{ 
    "ethtool": {
        "defaults": {
            "link-duplex": "full"
        },
        "iface_defaults": {
            "swp1": {
                "link-autoneg": "on", 
                "link-speed": "1000"
            },
            "swp16": {
                "link-autoneg": "off",
                "link-speed": "10000"
            },
            "swp50": {
                "link-autoneg": "off",
                "link-speed": "100000",
                "link-fec": "rs"
            }
        }
    },
    "address": {
        "defaults": { "mtu": "9000" }
    }
}

Configuring Breakout Ports

Cumulus Linux has the ability to:

  • Break out 100G switch ports into the following with breakout cables:
    • 2x50G, 4x25G, 4x10G
  • Break out 40G switch ports into four separate 10G ports for use with breakout cables.
  • Combine (also called aggregating or ganging) four 10G switch ports into one 40G port for use with a breakout cable (not to be confused with a bond).

To configure a 4x25G breakout port, first configure the port to break out then set the link speed:

cumulus@switch:~$ net add interface swp3 breakout 4x
cumulus@switch:~$ net add interface swp3s0-3 link speed 25000
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit

These commands create 4 interfaces in the /etc/network/interfaces file named as follows:

cumulus@switch:~$ cat /etc/network/interfaces
 
...
 
auto swp3s0
iface swp3s0
 
auto swp3s1
iface swp3s1
 
auto swp3s2
iface swp3s2
 
auto swp3s3
iface swp3s3
 
...

On Dell switches with Maverick ASICs, you configure breakout ports on the 100G uplink ports by manually editing the /etc/cumulus/ports.conf file. You need to specify either 4x10 or 4x25 for the port speed. For example, on a Dell S4148F-ON switch, to break out swp26 into 4 25G ports, you would modify the line starting with “26=” in ports.conf as follows:

cumulus@switch:~$ sudo nano /etc/cumulus/ports.conf
 
...
 
# QSFP+ ports
#
# <port label 27-28> = [4x10G|40G]
 
27=disabled
28=disabled
 
# QSFP28 ports
#
# <port label 25-26, 29-30> = [4x10G|4x25G|2x50G|40G|50G|100G]
 
25=100G
26=4x25G
29=100G
30=100G
 
...

Then you need to configure the breakout ports in the /etc/network/interfaces file:

cumulus@switch:~$ sudo nano /etc/network/interfaces
 
...
 
auto swp26s0
iface swp26s0
 
auto swp26s1
iface swp3s1
 
auto swp26s2
iface swp26s2
 
auto swp26s3
iface swp26s3
 
...

You cannot use NCLU to break out the uplink ports.

On Mellanox switches, you need to disable the next port (see below). In this example, you would also run the following before committing the update:

cumulus@switch:~$ net add interface swp4 breakout disabled

When you commit your change configuring the breakout ports, switchd restarts to apply the changes. The restart interrupts network services.

The breakout port configuration is stored in the /etc/cumulus/ports.conf file.

/etc/cumulus/ports.conf varies across different hardware platforms. Check the current list of supported platforms on the hardware compatibility list.

A snippet from the /etc/cumulus/ports.conf on a Dell S6000 switch (with a Trident II+ ASIC) where swp6 is broken out looks like this:

cumulus@switch:~$ cat /etc/cumulus/ports.conf 
# ports.conf --
#
# This file controls port aggregation and subdivision.  For example, QSFP+
# ports are typically configurable as either one 40G interface or four
# 10G/1000/100 interfaces.  This file sets the number of interfaces per port
# while /etc/network/interfaces and ethtool configure the link speed for each
# interface.
#
# You must restart switchd for changes to take effect.
#
# The DELL S6000 has:
#     32 QSFP ports numbered 1-32
#     These ports are configurable as 40G, split into 4x10G ports or
#     disabled.
#
#     The X pipeline covers QSFP ports 1 through 16 and the Y pipeline
#     covers QSFP ports 17 through 32.
#
#     The Trident2 chip can only handle 52 logical ports per pipeline.
#
#     This means 13 is the maximum number of 40G ports you can ungang
#     per pipeline, with the remaining three 40G ports set to
#     "disabled". The 13 40G ports become 52 unganged 10G ports, which
#     totals 52 logical ports for that pipeline.
#
# QSFP+ ports
#
# <port label 1-32> = [4x10G|40G|disabled]
1=40G
2=40G
3=40G
4=40G
5=40G
6=4x
7=40G
8=40G
9=40G
10=40G
11=40G
12=40G
13=40G
14=40G
15=40G
16=40G
17=40G
18=40G
19=40G
20=40G
21=40G
22=40G
23=40G
24=40G
25=40G
26=40G
27=40G
28=40G
29=40G
30=40G
31=40G
32=40G

For switches with ports that support 100G speeds, you can break out any 100G port into a variety of options: four 10G ports, four 25G ports, two 40G ports or two 50G ports. Keep in mind that you cannot have more than 128 total logical ports on a Broadcom switch.

The Mellanox SN2700, SN2700B, SN2410, and SN2410B switches both have a limit of 64 logical ports in total. However, if you want to break out to 4x25G or 4x10G, you must configure the logical ports as follows:

  • You can only break out odd-numbered ports into 4 logical ports.
  • You must disable the next even-numbered port.

These restrictions do not apply to a 2x50G breakout configuration.

For example, if you have a 100G Mellanox SN2700 switch and break out port 11 into 4 logical ports, you must disable port 12 by running net add interface swp12 breakout disabled, which results in this configuration in /etc/cumulus/ports.conf:

...

11=4x 12=disabled

There is no limitation on any port if interfaces are configured in 2x50G mode.

Here is an example showing how to configure breakout cables for the Mellanox Spectrum SN2700.

Removing a Breakout Port

To remove a breakout port, you need to do the following:

  1. Remove the breakout port interfaces using NCLU, then commit the change. Continuing with the original example:

    cumulus@switch:~$ net del interface swp3s0
    cumulus@switch:~$ net del interface swp3s1
    cumulus@switch:~$ net del interface swp3s2
    cumulus@switch:~$ net del interface swp3s3
    cumulus@switch:~$ net pending
    cumulus@switch:~$ net commit
    
  2. Manually edit the /etc/cumulus/ports.conf file to configure the interface for the original speed, then save your changes:

    cumulus@switch:~$ sudo nano /etc/cumulus/ports.conf 
         
    ...
         
    2=100G
    3=100G
    4=100G
         
    ...
    
  3. Restart switchd.

Combining Four 10G Ports into One 40G Port

You can gang (aggregate) four 10G ports into one 40G port for use with a breakout cable, provided you follow these requirements:

  • You must gang four 10G ports in sequential order. For example, you cannot gang swp1, swp10, swp20 and swp40 together.
  • The ports must be in increments of four, with the starting port being swp1 (or swp5, swp9, or so forth); so you cannot gang swp2, swp3, swp4 and swp5 together.

For example, to gang swp1 through swp4 into a 40G port, run:

cumulus@switch:~$ net add int swp1-4 breakout /4 
cumulus@switch:~$ net pending
cumulus@switch:~$ net commit

These commands create the following configuration snippet in the /etc/cumulus/ports.conf file:

# SFP+ ports#
# <port label 1-48> = [10G|40G/4]
1=40G/4
2=40G/4
3=40G/4
4=40G/4
5=10G

Logical Switch Port Limitations

100G and 40G switches can support a certain number of logical ports, depending upon the manufacturer; these include:

  • Mellanox SN2700 and SN2700B switches
  • Switches with Broadcom Tomahawk, Trident II and Trident II+ chipsets (check the HCL)

Before you configure any logical/unganged ports on a switch, check the limitations listed in /etc/cumulus/ports.conf; this file is specific to each manufacturer.

For example, the Dell S6000 ports.conf file indicates the logical port limitation like this:

# ports.conf --
#
# This file controls port aggregation and subdivision.  For example, QSFP+
# ports are typically configurable as either one 40G interface or four
# 10G/1000/100 interfaces.  This file sets the number of interfaces per port
# while /etc/network/interfaces and ethtool configure the link speed for each
# interface.
#
# You must restart switchd for changes to take effect.
#
# The DELL S6000 has:
#     32 QSFP ports numbered 1-32
#     These ports are configurable as 40G, split into 4x10G ports or
#     disabled.
#
#     The X pipeline covers QSFP ports 1 through 16 and the Y pipeline
#     covers QSFP ports 17 through 32.
#
#     The Trident2 chip can only handle 52 logical ports per pipeline.
#
#     This means 13 is the maximum number of 40G ports you can ungang
#     per pipeline, with the remaining three 40G ports set to
#     "disabled". The 13 40G ports become 52 unganged 10G ports, which
#     totals 52 logical ports for that pipeline.

The means the maximum number of ports for this Dell S6000 is 104.

Mellanox SN2700 and SN2700B switches have a limit of 64 logical ports in total. However, the logical ports must be configured in a specific way. See the note above.

Using ethtool to Configure Interfaces

The Cumulus Linux ethtool command is an alternative for configuring interfaces as well as viewing and troubleshooting them.

For example, to manually set link speed, auto-negotiation, duplex mode and FEC on swp1, run:

cumulus@switch:~$ sudo ethtool -s swp1 speed 25000 autoneg off duplex full
cumulus@switch:~$ sudo ethtool --set-fec swp1 encoding off

To view the FEC setting on an interface, run:

cumulus@switch:~$ sudo ethtool --show-fec swp1FEC parameters for swp1:
Auto-negotiation: off
FEC encodings : RS

Verification and Troubleshooting Commands

Statistics

High-level interface statistics are available with the net show interface command:

cumulus@switch:~$ net show interface swp1
 
    Name    MAC                Speed      MTU  Mode
--  ------  -----------------  -------  -----  ---------
UP  swp1    44:38:39:00:00:04  1G        1500  Access/L2
 
 
Vlans in disabled State
-------------------------
br0
 
 
Counters      TX    RX
----------  ----  ----
errors         0     0
unicast        0     0
broadcast      0     0
multicast      0     0
 
 
LLDP
------  ----  ---------------------------
swp1    ====  44:38:39:00:00:03(server01)

Low-level interface statistics are available with ethtool:

cumulus@switch:~$ sudo ethtool -S swp1
NIC statistics:
     HwIfInOctets: 21870
     HwIfInUcastPkts: 0
     HwIfInBcastPkts: 0
     HwIfInMcastPkts: 243
     HwIfOutOctets: 1148217
     HwIfOutUcastPkts: 0
     HwIfOutMcastPkts: 11353
     HwIfOutBcastPkts: 0
     HwIfInDiscards: 0
     HwIfInL3Drops: 0
     HwIfInBufferDrops: 0
     HwIfInAclDrops: 0
     HwIfInBlackholeDrops: 0
     HwIfInDot3LengthErrors: 0
     HwIfInErrors: 0
     SoftInErrors: 0
     SoftInDrops: 0
     SoftInFrameErrors: 0
     HwIfOutDiscards: 0
     HwIfOutErrors: 0
     HwIfOutQDrops: 0
     HwIfOutNonQDrops: 0
     SoftOutErrors: 0
     SoftOutDrops: 0
     SoftOutTxFifoFull: 0
     HwIfOutQLen: 0

Querying SFP Port Information

You can verify SFP settings using ethtool -m . The following example shows the output for 1G and 10G modules:

cumulus@switch:~# sudo ethtool -m | egrep '(swp|RXPower :|TXPower :|EthernetComplianceCode)'
 
swp1: SFP detected
              EthernetComplianceCodes : 1000BASE-LX
              RXPower : -10.4479dBm
              TXPower : 18.0409dBm
swp3: SFP detected
              10GEthernetComplianceCode : 10G Base-LR
              RXPower : -3.2532dBm
              TXPower : -2.0817dBm

Caveats and Errata

Timeout Error on Quanta LY8 and LY9 Switches

On Quanta T5048-LY8 and T3048-LY9 switches, an “Operation timed out” error occurs while removing and reinserting QSFP module.

The QSFPx2 module cannot be removed while the switch is powered on, as it is not hot-swappable. However, if this occurs, you can get the link to come up; however, this involves restarting switchd, which disrupts your network.

On the T3048-LY9, run the following commands:

cumulus@switch:~$ sudo echo 0 > qsfpd_power_enable/value
cumulus@switch:~$ sudo rmmod quanta_ly9_rangeley_platform 
cumulus@switch:~$ sudo modprobe quanta_ly9_rangeley_platform
cumulus@switch:~$ sudo systemctl restart switchd.service

On the T5048-LY8, run the following commands:

cumulus@switch:~$ sudo echo 0 > qsfpd_power_enable/value
cumulus@switch:~$ sudo systemctl restart switchd.service

swp33 and swp34 Disabled on Some Switches

The front SFP+ ports (swp33 and swp34) are disabled in Cumulus Linux on the following switches:

  • Dell Z9100-ON
  • Penguin Arctica 3200-series switches (the 3200C, 3200XL and 3200XLP)
  • Supermicro SSE-C3632S

These ports appear as disabled in the /etc/cumulus/ports.conf file.

ethtool Shows Incorrect Port Speed on 100G Mellanox Switches

After setting interface speed to 40G by editing the ports.conf file on a Mellanox switch, ethtool still shows the speed as 100G.

This is a known issue whereby ethtool does not update after restarting switchd, so it continues to display the outdated port speed.

To correctly set the port speed, use NCLU or ethtool to set the speed instead of hand editing the ports.conf file.

For example, to set the speed to 40G using NCLU:

cumulus@switch:~$ net add interface swp1 link speed 40000 

Or using ethtool:

cumulus@switch:~$ sudo ethtool -s swp1 speed 40000